مواقع التدريسيينجامعة الكوفة
faris abbas jawad uraiyer
Assistant Professor

faris abbas jawad uraiyer

0Publications
0Lectures

About

Certificates
1-B.Sc./ University of Technology/Baghdad /1986
M.Sc. / Kufa University /Al-Najaf/2003
Ph.D./ Jamia Millia Islamia /Delhi/ 2014
1-Faris Abbas Jawad , Effect of using bracing members in reducing thermal effects on long building, kufa journal of engineering, Vo. 1, No.1 ,2009
2- F.A. J Uriayer and Mehtab Alam, capacity enhancement of steel by compositing with carbon fiber reinforce polymer, Proc Indian Natn Sci Acad 79 No. 4, 2013.
3- Faris A. Uriayer and Mehtab Alam, Mechanical properties of steel-CFRP composite specimen under uniaxial tension, Steel and Composite Structures, Vol. 15, No. 6 ,2013

4 Faris Abbas Jawad Uriayer, and Mehtab Alam, Steel–CFRP Composite (CFRP Laminate Sandwiched between Mild Steel Strips) and It’s Behavior as Stirrup in Beams, World Academy of Science, Engineering and Technology Vol:73 2013

5- Faris Abbas Jawad Uriayer ,The new Steel-CFRP composite specimen (CFRP laminates sandwiched between two steel strips) and its behavior under Uniaxial tension, international journal of civil and structural Engineering volume 3, no 1, 2011

6-Faris A. Uriayer and Mehtab Alam, Steel–CFRP composite and their shear response as vertical stirrup in beams, Steel and Composite Structures, Vol. 18, No. 5 ,2015

1- فارس عباس جواد , دراسة تاثير الركام المنقطغ التسلسل والركام الفاشل بالتدرج على مقاومة الانضغاط الخرسانة, مجلة جامعة بابل/العلوم الصرفة والتطبيقية / العدد 1 /المجلد 17/ 2009

Publications

9
2017

The effect of connection on the bearing capacity of bolted connections

Authorsfaris abbas jawad
JournalJournal of babylon University
Abstract

Journal of Babylon University

2016

EFFECT OF BOLT DIRECTION ON THE BEARING CAPACITY OF DOUBLE SHEAR CONNECTIONS

AuthorsFaris A. Jawad, Salah Talib Nimnim, Muhammed Abed Attiya
JournalKufa Journal of Engineering
Abstract

The direction of bolts and its effect on the bearing capacity of double shear bolted connections has been examined in this paper. Sixteen specimens with up to four bolts have been tested under tensile load. These specimens have been sorted into two series (L, T) according to the bolt direction with applied loads The experimental results have clearly indicated that the bearing capacity of connections had been considerably affected by changing the direction of bolts. With tear-out failure, All specimens of L series showed high bearing capacity and good ductility while block shear failure was the distinguishing feature of specimens of T series.

2015

Steel–CFRP composite and their shear response as vertical stirrup in beams

AuthorsFaris A. Uriayer, Mehtab Alam
JournalSteel and Composite Structures
Abstract

An experimental study was conducted for the effectiveness of steel-CFRP composite (CFRP laminates sandwiched between two steel strips) as stirrups in concrete beam to carry shearing force and comparison was made with conventional steel bar stirrups. A total numbers of 8 concrete beams were tested under four point loads. Each beam measured 1,600 mm long, 160 mm width and 240 mm depth. The beams were composed of same grade of concrete, with same amount of flexural steel but different shear reinforcements. The main variables include, type of stirrups (shape of stirrups and number of CFRP layers used in each stirrup) and number of stirrups used in shear spans. After getting on an excellent closeness between the values of ultimate shear resistance and ultimate tensile load of steel-CFRP stirrups, it could be concluded that the steel-CFRP stirrups represent the effective solution of premature failure of FRP stirrups at the bends.

2013

capacity enhancement of steel by compositing with carbon fiber reinforce polyme

AuthorsF.A. J Uriayer , d Mehtab Alam
JournalProc Indian Natn Sci Acad
Abstract

This paper introduces new specimens of Steel-Carbon Fibre Reinforced Polymer composite developed in accordance with standard test method and definition for mechanical testing of steel (ASTM –A370). The main purpose of this research is to study the behaviour of steel-CFRP composite specimen under uniaxial tension to use it in beams in lieu of traditional steel bar reinforcement. Eighteen specimens were prepared and divided into six groups, depending upon the number of the layers of CFRP. Uniaxial tensile tests were conducted to determine yield strength and ultimate strength of specimens. Test results showed that the stress-strain curve of the composite specimen was bilinear prior to the fracture of CFRP laminate. The tested composite specimens displayed a large difference in strength with remarkable ductility. The ultimate load for Steel-Carbon Fibre Reinforced Polymer composite specimens was found using the model proposed by Wu et al. (2010) and nonlinear FE analysis. The ultimate loads obtained from FE analysis are found to be in good agreement with experimental ones. However, ultimate loads obtained applying Wu model are significantly different from experimental/ F E ones. This suggested modification of Wu model. Modified Wu’s model which gives a better estimate for the ultimate load of Steel-Carbon Fibre Reinforced Polymer (SCFRP) composite specimen is presented in this paper

2013

Mechanical properties of steel-CFRP composite specimen under uniaxial tension

AuthorsFaris A. Uriayer, Mehtab Alam
JournalSteel and Composite Structures
Abstract

This paper introduces new specimens of Steel-Carbon Fibre Reinforced Polymer composite developed in accordance with standard test method and definition for mechanical testing of steel (ASTM –A370). The main purpose of this research is to study the behaviour of steel-CFRP composite specimen under uniaxial tension to use it in beams in lieu of traditional steel bar reinforcement. Eighteen specimens were prepared and divided into six groups, depending upon the number of the layers of CFRP. Uniaxial tensile tests were conducted to determine yield strength and ultimate strength of specimens. Test results showed that the stress-strain curve of the composite specimen was bilinear prior to the fracture of CFRP laminate. The tested composite specimens displayed a large difference in strength with remarkable ductility. The ultimate load for Steel-Carbon Fibre Reinforced Polymer composite specimens was found using the model proposed by Wu et al. (2010) and nonlinear FE analysis. The ultimate loads obtained from FE analysis are found to be in good agreement with experimental ones. However, ultimate loads obtained applying Wu model are significantly different from experimental/ F E ones. This suggested modification of Wu model. Modified Wu’s model which gives a better estimate for the ultimate load of Steel-Carbon Fibre Reinforced Polymer (SCFRP) composite specimen is presented in this paper.

2013

Steel–CFRP Composite (CFRP L Mild Steel Strips) and It’s Behavior as Stirrup in aminate Sandwiched betweenBeams

Authors Faris Abbas Jawad Uriayer, Mehtab Alam
JournalWorld Academy of Science, Engineering and Technology
Abstract

Steel–CFRP Composite (CFRP L Mild Steel Strips)

2012

The new Steel-CFRP composite specimen (CFRP laminates sandwiched between two steel strips) and its behaviour under Uniaxial tension

AuthorsFaris Abbas Jawad Uriayer
JournalINTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING
Abstract

This paper introduces new specimen of steel-Carbon Fibre Reinforce Polymer (CFRP) composite developed in accordance with standard test method and definition for mechanical testing of steel (ASTM –A370). Fifteen specimens were prepared and divided into five groups depending upon a number of the layers of CFRP. Uniaxial tensile tests were conducted to determine yield strength and ultimate strength of specimens. Test results showed that the stress-strain curves of the composite specimens were bilinear prior to the fracture of laminate. The tested composite specimens displayed a large difference in strength with ductility. Finally, the proposed model by (Gang et al. 2010) was modified in this paper to give better estimate of the ultimate load of specimen. The estimated values agreed very well with experimental ones.

2009

Effect of using bracing members in reducing thermal effects on long building,

AuthorsFaris Abbas Jawad
Journalkufa journal of engineering
Abstract

kufa journal of engineering

2009

دراسة تاثير الركام المنقطغ التسلسل والركام الفاشل بالتدرج على مقاومة الانضغاط الخرسانة,

Authors فارس عباس جواد
Journalمجلة جامعة بابل/العلوم الصرفة والتطبيقية
Abstract

مجلة جامعة بابل/العلوم الصرفة والتطبيقية

Lectures

3
View details