Studying Effects of Calcium Oxide Nanoparticles on Dentinogenesis in Male Wistar Rats
الباحثونBushra Habeeb Al-Maula، Zena Jehad Wally, Mohanad Jameel Najm Al-Magsoosi, Rasha Hatem Dosh, Ruba M Mustafa, Suhad Jabbar Hamed Al-Nasrawi, Abdullatif Alfutimie, Julfikar Haider
المجلةInternational Journal of Dentistry
مختصر البحثThis study aimed to evaluate potential impacts of calcium oxide nanoparticles (CaO-NPs) at different dosages on predentin thickness, number of blood vessels, periodontal ligament thickness, and blood glucose level of Wistar rats. Twelve rats were randomly gathered into four groups, untreated (control) and CaO-NP-treated groups at three concentrations (25, 50, and 100 mg/kg of the body weight) over a period of 60 days. Histological investigation was performed on twenty-four lower incisor teeth extracted from all the tested groups under a light microscope, and an automatic Fujifilm was used to measure the blood glucose level. The results showed that regular nanoparticle treatment significantly increased predentin and periodontal ligament thicknesses, a gradual decrease in vascularization in the pulp tissue, and an increase in the blood glucose level as the dosages of nanoparticles administered to the rats increased. Administration of the CaO-NPs at low dosage (25 mg/kg) could be beneficial for the growth and integrity of teeth and dentinal tissues in rats.
Chemical Characterisation of Silanised Zirconia Nanoparticles
and Their Effects on the Properties of
PMMA-Zirconia Nanocomposites
الباحثونSaleh Zidan، Nikolaos Silikas 2 , Suhad Al-Nasrawi 3 , Julfikar Haider 2,4 , Abdulrahman Alshabib 5,
Alshame Alshame 6 and Julian Yates
المجلةMaterials 2021, 14,
3212.
مختصر البحثAbstract: Objectives: The objective of this study was to investigate the mechanical properties of highimpact
(HI) heat-cured acrylic resin (PMMA) reinforced with silane-treated zirconia nanoparticles.
Methods: Forty-five PMMA specimens reinforced with zirconia were fabricated and divided into three
groups: Pure HI PMMA (control group), PMMA reinforced with 3 wt.% of non-silanised zirconia
nanoparticles and PMMA reinforced with 3 wt.% of silanised zirconia nanoparticles. Silanised
and non-silanised zirconia nanoparticles were analysed with Fourier Transform Infrared (FTIR)
Spectroscopy. For measuring the flexural modulus and strength, a Zwick universal tester was
used, and for surface hardness, a Vickers hardness tester were used. Furthermore, raw materials and
fractured surfaces were analysed using Scanning Electron Microscopy (SEM). A one-way ANOVA test
followed by a post-hoc Bonferroni test was employed to analyse the data. Results: The results showed
that the mean values for flexural strength (83.5 6.2 MPa) and surface hardness (20.1 2.3 kg/mm2)
of the group containing 3 wt.% treated zirconia increased significantly (p < 0.05) in comparison to
the specimens in the group containing non-treated zirconia (59.9 7.1 MPa; 15.0 0.2 kg/mm2)
and the control group (72.4 8.6 MPa; 17.1 0.9 kg/mm2). However, the group with silanised
zirconia showed an increase in flexural modulus (2313 161 MPa) but was not significantly different
(p > 0.05) from the non-silanised group (2207 252 MPa) and the control group (1971 235 MPa).
Conclusion: Silane-treated zirconia nano-filler improves the surface hardness and flexural strength of
HI PMMA-zirconia nanocomposites, giving a potentially longer service life of the denture base.
Impact of Peracetic Acid on the Dynamic Cyclic Fatigue of Heat-Treated Nickel-Titanium Rotary Endodontic Instrument
الباحثونSuhad Al-Nasrawi، ,Zuha Ayad Jaber, Nibrass Talib Al-Quraine, Abtesam Imhemed Aljdaimi Sattar JabbarAbdul-ZahraAl-Hmedat, SalehZidan, Julfikar Haide
المجلةInternational Journal of Dentistry
مختصر البحثPeracetic acid (PAA) is widely used as a sterilizing/disinfecting agent, and, in endodontics, it has been introduced as a promising
irrigant in root canal treatment. It has been used at different concentrations to achieve various functions. However, endodontic
instruments in contact with PAA of a certain concentration may affect their fatigue resistance. /erefore, the aim of this study was
to investigate the impact of PAA on the cyclic fatigue resistance of three commercial heat-treated nickel-titanium (NiTi) rotary
files. /ree types of heat-treated NiTi rotary files were selected: One Curve (OC), ProTaper Gold (PTG), and Wave One Gold
(WOG). Each type was divided into three subgroups (n � 6 for each file type): (1) untreated instruments; (2) files immersed in
0.002% PAA; and (3) files immersed in 0.35% PAA. /e performance of each file type was tested in a simulated canal. /e number
of cycles to fracture (NCF) was determined to assess cyclic fatigue resistance of the files. Independent sample t-test was applied to
compare each treated file within a subgroup with its respective control group, and one-way ANOVA was used for comparison
among the main groups. All types of tested files revealed a significant decline in the cyclic fatigue resistance after exposure to
0.002% PAA except the PTG (P � 0.209). After exposure of the files to a higher concentration (0.35% PAA), a dramatic reduction
was demonstrated by all the groups. Before and after exposure of the files to PAA, PTG displayed the highest cyclic fatigue
resistance, followed by the WOG, while the OC showed the lowest resistance. Exposure of heated-treated NiTi files to PAA in a
relatively high or low concentration adversely affects the cyclic fatigue resistance. /e PTG files demonstrated the best performance among the tested types and can be disinfected with 0.002% PAA for clinical purpose.
Evaluating in-Vitro Performance of Novel Nickel-Titanium Rotary System (TruNatomy) based on debris extrusion and preparation time from Severely Curved Canals
الباحثونRuba Mustafa، Taher Al Omari
Suhad Jabbar Al-nasrawi
Rami Al Fodeh
Alaa Dkmak
المجلةJournal of Endodontics
مختصر البحثIntroduction This laboratory-based study aimed to investigate the quantitative amount of apically extruded debris from severely curved root canals and preparation time for the novel rotary system, TruNatomy (TN), compared to Reciproc Blue (RCB), HyFlex (HCM, HEDM) and ProTaper Next (PTN) rotary systems. Methods One hundred mandibular molar human teeth with sever curvature of the mesiobuccal canal (25º- 45º) were included in the present study. The specimens were randomly distributed in balanced five groups (n=20): TN, RCB, HCM, PTN, and HEDM. The amount of extruded debris for each group during instrumentation at body temperature was collected in an Eppendorf tube. After desiccation, the mean debris weights for each group were calculated. The total preparation time for each group was also recorded. Data were statistically analysed using the Kruskal–Wallis test at a significance level of P < 0.05. Results HCM and HEDM groups extruded a significantly higher amount of debris than the other tested groups (P < 0.001). TN extruded the least amount of debris, but it was not significantly different compared to the RCB and PTN groups (P > 0.05). In terms of preparation time, the TN group did not show any significant difference compared to the other groups. Conclusions All instrumentation systems extruded debris. The TN was among the groups that produced the lowest amount of apically extruded debris that is probable clinically acceptable, since it is equitable to two popular systems and statistically significantly less than two other popular systems studied.
The Effect of Biodentine Maturation Time on Resin Bond Strength
When Aged in Artificial Saliva
الباحثونRuba M. Mustafa، Suhad J. Al-Nasrawi
Abtesam I. Aljdaimi
المجلة
International Journal of Dentistry
مختصر البحثBiodentine is a calcium silicate cement (CSC) that has been broadly applied in vital pulp therapy. 'e quality of the Biodentinecomposite
bond has a significant effect on the longevity of the definitive restoration.'eaim of this study is to investigate the shear
bond strength (SBS) between Biodentine and composite restoration at different maturation times of Biodentine aged in artificial
saliva. Fifteen Biodentine discs were allocated into three groups (n � 5) based on the timeframe of performance of composite
restoration: immediate (after 12 min), after 14 days, and after 28 days of Biodentine maturation. Total etch and rinse adhesive
system and bulk-fill regular resin composite were used. 'e shear bond strength and the failure pattern were assessed. One-way
ANOVA with the Bonferroni post hoc test was applied for statistical analysis at p < 0.05. 'e highest (32.47 ± 8.18 MPa) and the
lowest (4.08 ± 0.81 MPa) SBS values were recorded for 14 days and 12 min groups, respectively. Significant statistical differences
were reported among the groups, and a high statistically significant difference was found between the immediate group and the
other groups. Adhesive failure patterns were evident in all groups. More clinically acceptable bond strength between the
Biodentine and overlaid composite restoration is at 14 days after Biodentine maturation. Delaying the coverage of Biodentine later
than 14 days may significantly reduce the SBS. Using the artificial saliva as an aging medium may affect the SBS between
Biodentine and composite material.
Comparative Study to Evaluate the Antimicrobial Effect of MTAD, 17% EDTA, and 3% NaOCl- Against Enterococcus faecalis in Primary Teeth for Root Canals Therapy
(in Vitro Study)
الباحثونSarmad A. Hameed1 ، Sana’a Abdulrazzaq Ibrahim2 Suhad Al-Nasrawi3
المجلةMedico-Legal update
مختصر البحثAim: This study presented to compare the antimicrobial effect of MTAD, 17% EDTA, and 3% NaOCl, against Enterococcus faecalis (E. faecalis).
Methodology: The study utilized 40 extracted human primary teeth with single root canal. The samples were instrumented and sterilized, and then, these teeth were infected with E. faecalis for 2 weeks, after that tooth were divided randomly into 2 groups according to the irrigants used. All the samples were incubated in brain heart infusion (BHI) broth. Irrigation processes were completed according to each material instruction. The effectiveness of irrigants was evaluated by comparison between the pre-irrigation and post- irrigation samples using serial dilution (CFU/ml).
Statistical analysis was done using one-way anova with dunnett t3 post hoc test.
Results: all samples treated with MTAD showed nearly complete absence of bacteria. the samples treated 3% NaOCl and 17% EDTA showed similar result to the first group, Statistical analysis of the data using dunnett t3 test showed there is no significant difference between the groups (P > 0.05).
Conclusion: The study concluded that MTAD was effective as 3% NaOCl -17% EDTA against E. faecalis.