مواقع التدريسيينجامعة الكوفة
Saif Watheq Mohammed Ali Al-Turaihi
Assistant Professor

Saif Watheq Mohammed Ali Al-Turaihi

0Publications
0Lectures
0News

About

Saif completed his Bachelor degree at Kufa University/ College of Engineering 2007-2008 in general mechanical engineering science. In 2011, Saif had gotten his Master degree from Baghdad University in Fluid and Thermal Science. He had been appointed as a Lecturer in Kufa University/ college of Engineering/ Mechanical Department. Saif used to teach gas dynamic, turbo-machinery, and thermo-dynamic courses for three years. In 2014, Saif travelled to USA to complete his Ph.D at Lehigh University. In 2019, Saif Completed his Ph.D. Saif has number of published papers in the scientific journals.

Publications

17
2023

Investigating the Thermal Behavior and Productivity of a Double Slope Solar Still System Integrated with a Basin of Phase Change Material Supported by an Experimental Data

AuthorsHazim Jassim Jaber, Qais A. Reshack, Qahtan A. Abed, Saif W. Mohammed Ali
JournalAIP Conference Proceedings
Abstract

A numerical model was formulated in the present study to investigate the performance of a double slope solar still system integrated with a PCM (Phase Change Material) basin. The thermal behavior and productivity of the solar still was investigated under different solar irradiation fluxes corresponding to different operating time hours. OpenFOAM V.8 code was used to solve the model using finite volume method for solution and scheme discretization. In addition, the solidity phase fraction gradient was studied under similar conditions. The numerical results were supported by an experimental data from literature conducted to the same project of the current work to validate the formulated numerical model. The numerical test of the double slope solar still was investigated under two different solar fluxes applied on both the south and north sides of the glass cover. Results show that temperature gradient on the south part side of the solar still is higher than the gradient values in the north part side. Additionally, it was found that temperature increases toward water surface because of the heat stored in the water and PCM. Regarding the solidity phase fraction of the PCM, it was found that the PCM is fused partially as the melting temperature can’t be reached. However, because the upper layers in the PCM region are closer to the heat source comes from the solar still, solidity fraction of these layers is higher than the fraction values in the layers below. Indeed, the phase fraction gradient is dependent on the solar flux, higher solar flux, higher phase fraction gradient. Moreover, interesting finding is that the productivity increases with the operating time hours despite the reduction in the solar irradiation where the maximum productivity reached is 0.450 (l/m2.hr) at 4:00 PM and solar irradiation equals to 466 (W/m2) while at 12:00 PM where the irradiation reaches its maximum value (1208 W/m2), the productivity is lower (0.19 l/m2.hr). The numerical behavior of the accumulated and instantaneous productivity is agreeable and acceptable in compare with the experimental behavior where the average error of all instantaneous productivity values does not pass 20%.

2023

Investigating the thermal performance of air-cooling system integrated with TEC modules: Transient numerical simulation

AuthorsTaif M. Mansoor, Saif W. Mohammed Ali, Hussam H. Jabbar
JournalElsevier
Abstract

The current study represents a developed 3-D numerical transient model to a complete indirect non-evaporative cooling system integrated with an assisted TEC unit using OpenFOAM V.9 source code. The TEC model was developed using a hand-written code as a source added to the energy equation. The primary air temperature was a criterion to compare between three cases of environment’s temperature: low mode (299 K), medium mode (309 K), and high mode (319 K). A new dimensionless factor called by Heat Flux Ratio (HFR) is derived to evaluate the thermal performance. In addition, wall heat flux and temperature difference along the vertical air channel were the parameters used for comparison. The complete system was constructed and validated according to number of experimental and theoretical studies from literature. Furthermore, all cases were tested under five different air inlet velocities: 0.75 m/s, 1 m/s, 1.25 m/s, 1.5 m/s, and 1.75 m/s. Results show that HFR values increase as time increases. In addition, it was found that HFR increases with the reduction in the velocity. Moreover, it was found that higher temperature difference can be reached at the lowest velocity (0.75 m/s) while the minimum difference would be at the highest velocity (1.75 m/s) with the error between modes doesn’t pass (2.5%). On the other hand, the highest wall heat flux approached at the highest velocity (1.75 m/s) and vice versa where the error doesn’t exceed (2.85%) between the modes. Finally, the validation shows good and acceptable agreement in COP values of the system with both experimental and theoretical works form literature where the error is ranged between (20.3% and 3.64%).

2023

Assessment of Thermal Performance of Non-Evaporative Cooling System Assisted with TEC Models at High Temperature Climate

Authors Hussam H. Jabbar, Mohammed A. Al-Tayyar, Taif M. Mansoor, Saif W. Mohammed Ali
JournalApplied Mechanics and Materials
Abstract

In this work, a non-evaporative cooling system is used with an assisted thermoelectric cooler (TEC) devices module. The system was proposed as an alternative cooling system in the high temperature climate to overcome the high energy consumption of traditional air-conditioning compression cycle. The open source Open FOAM V.9 was used to solve the transient effect of 3D model of indirect non-evaporative cooling system. The primary air temperature was set to 319 . While, the air flow was tested under four different air inlet velocities: 0.75 m/s, 1 m/s, 1.25 m/s, and 1.5 m/s. the validation shows good and acceptable agreement in COP values of the system with both experimental and theoretical works from literature within an error between (12.9 % and 9.5 %). Results show that the temperate difference value on a slice through the length of the air channel starts to decrease as velocity increasing. For example, at the last timesteps of each velocity, the temperature difference reaches about (~10 oK) when velocity is (0.75 m/s) starting from the first quarter of the channel, while the same difference in temperature not reached until the half way of the channel from the channel inlet when velocity is (1.5 m/s). Revealing that even though the percentage increase in the velocity is about 50%, the change in the temperature difference value between the inlet and outlet of the channel is about 1.2%. The local Nusselt number shows that steady state heat transfer reached very quickly as the velocity increased (i.e., at 0.75 m/s at 12s while for 1.5 m/s at 4s). Notwithstanding, as the time processed the ( increases for all cases but becomes lower as the velocity increased. .

2021

Performance of Kaplan Turbine Operating at Design Condition

AuthorsMuhannad Altimemy, Saif Watheq, Justin Caspar, Alparslan Oztekin
JournalASME Collection
Abstract

Design and optimization using computational fluid dynamics to enhance the hydro turbine’s performance are becoming gradually more common because of its flexibility, minor detailed flow description, and cost-effectiveness. These features are not easily achievable in model testing. k–ω simulations conducted in OpenFOAM 7 characterize the flow structure inside an industrial-sized Kaplan turbine module operating at the peak design flowrate. The power signal, velocity, vorticity, and pressure field are presented over the blades and throughout the draft tube. Additionally, pressure fluctuations were probed along the draft tube wall. The simulation shows a tip vortex rope in the narrow gap between the blade tip and turbine casing. The strong influence of the swirl leaving the runner had a negative impact on the flow pressure fluctuation. Also, high vortical activity was presented near the draft tube wall, leading to turbine instability. It was demonstrated that the turbine generates 14.923 MW of average power. The power signal showed minor fluctuations induced by the vortical activity close to the runner region and the corresponding pressure fluctuations. The Fast Fourier Transform showed the system is dominated by low frequency, high amplitude fluctuations.

2021

Flow Characterization of an Industrial Size Francis Turbine Operating at Ultra-Low Load – The Effect of Water Injection

AuthorsMuhannad Altimemy, Justin Caspar, Saif Watheq, Alparslan Oztekin
JournalASME Collection
Abstract

Large Eddy Simulations (LES) are carried out for a Francis turbine operating at an ultra-low load with and without injection. The flow rate of the turbine is 40% of the design value. The injection aims to improve turbine operation for the already unstable base case away from the design flow rate. Tangential water injection was introduced through the draft tube wall in the same and opposite runner rotation direction. The injection angle was varied (15°, 30°, 45° and 60°). Two water injection rates were applied at 4% and 8 % of the optimal design flowrate. While injection with the 4% rate and 30° in the opposite runner rotation direction helped reduce pressure fluctuations downstream of the injection inlets; no injection configuration could completely mitigate the power and pressure fluctuations. The injection was found to increase the amplitude of pressure fluctuations close to the injection inlets by 2 to 20 times the magnitude of fluctuations without injection. There was a slight reduction in mean power production (4–10% loss) by injection. The high amplitude fluctuations were observed in power signals with and without the injection.

2021

Large Eddy Simulations of Francis Turbine Operating at Ultra-Low Loads

AuthorsMuhannad Altimemy, Justin Caspar , Saif Watheq , Alparslan Oztekin
JournalASME
Abstract

High-fidelity Large Eddy Simulations (LES) were conducted to characterize the spatial and temporal structure of turbulent flows in an industrial-sized Francis turbine running at 120% of the design flow rate. Injection at a 4% and 8% flow rate is applied and investigated as a mitigation method for pressure-induced fluctuations along the draft tube. Contours of velocity and vorticity in the draft tube are presented to examine the effects of water injection. Probes placed alongside the draft tube measure the pressure signal and compare both operational regimes to characterize the pressure fluctuations. The intensity of pressure fluctuations along the draft tube wall is an order of magnitude smaller compared to that at the center. As the injection is applied, the intensity of the pressure fluctuations along the draft tube wall is increased while the intensity of pressure fluctuations in the center of the draft tube is reduced. Pressure probes in the center of the draft tube measure an 86% to 57% reduction in amplitude for 4% to 8% flow rate injection, respectively. There is a 30% to 40% increase in fluctuations along the wall for 4% to 8% flow rate injection, respectively. These changes in flow structure are due to the dissipation of the vortex rope as the injection is applied.

2021

Francis Turbine Operation at Excess Flow Rate Using Large Eddy Simulation: The Effect of Water Injection

AuthorsMuhannad Altimemy, Justin Caspar, Saif Watheq, Alparslan Oztekin
JournalASME
Abstract

High-fidelity large eddy simulations (LES) were conducted to characterize the spatial and temporal structure of turbulent flows in an industrial-sized Francis turbine. The unit operated at 50% and 40% of the best efficiency design flowrate. Contours of vorticity, velocity, pressure, and iso-surfaces of Q-Criterion were presented to characterize the effects on the draft tube. Probes placed alongside the draft tube measure the pressure signal to investigate the flow-induced pressure fluctuations inside the turbine unit. The maximum intensity of pressure fluctuations at 50% partial load was 22.66% of the turbine head, while the strength of the pressure fluctuations was 26.36% at 40% partial load. A large number of unorganized smaller vortices observed in the draft tube contribute to the creation of pressure fluctuations. Two pressure modes can be easily recognized (1) high frequency with low amplitude pressure fluctuations and (2) low frequency with high amplitude fluctuations. These pressure fluctuations could be harmful to the structural integrity of the unit and also have undesirable influences on the operational stability of the hydro-turbines.

2020

An optimization for water requirement in natural gas combined cycle power plants equipped with once-through and hybrid cooling systems and carbon capture unit

AuthorsSaif Watheq Mohammed Ali, Nasser Vahedi, Carlos Romero, Alparslan Oztekin
JournalWater Energy Nexus
Abstract

A water-energy nexus analysis for a Natural Gas Combined Cycle power plant equipped with Post- Combustion Carbon Capture unit was studied. Once-through and hybrid indirect dry and wet cooling systems were considered. An optimization model was developed to minimize the water requirement in each of the cooling system. The model and numerical method were validated with previously reported experimental measurements. In once-through cooling system, the optimized mass flow rates were slightly less than the original operating condition. For hybrid cooling system, the effects of air to water ratio, humidity content, air wet bulb temperature, and the number of cycles of concentration on the water requirements were studied for a wide range of cooling load split factors. The difference in water requirement becomes insignificant when the cooling load exceeds 60%. It was shown that the increase in the number of cycles of concentrations reduces water losses within 5–6 cycles. It is recommended to consider dynamic control for the cooling system using the developed optimization algorithm to maintain optimum operating conditions. For the once-through cooling system, maintaining the least water withdrawal while protecting aquatic life is suggested. For hybrid cooling systems, keeping the split factor below 0.5 and optimizing water consumption and power penalty are recommended.

2020

Solar Integrated Unit to Reduce Power and Cooling Penalty of a Natural Gas Combined Cycle Plant integrated with a Carbon Capture System

AuthorsSaif W. Mohammed Ali, Sahib S. Ahmed, Nabeel A. Ghayadh
JournalIOP Conference Series: Materials Science and Engineering
Abstract

Integrating solar assisted plant with a carbon capture unit to provide the required reboiler heat duty has been recently investigated extensively to reduce the negative impact of carbon capture unit on plant performance. However, using solar assisted plant to provide the required energy in the reboiler of the stripper leads to increase plant's condenser duty unfavorably. In the present study, two novel configurations have been proposed for a concentrated solar assisted power plant to generate the required reboiler duty in the stripper of a post-combustion carbon capture unit (PCCC-SAPP) in a (630 MWe) natural gas combined cycle (NGCC) power plant to reduce both the condenser duty and power penalty of the plant simultaneously. In the present study, both the solar plant and plant's low-pressure steam (LPS) are contributing to deliver the required reboiler thermal energy in the first method while the extraction is from the cooling system load in addition to the solar plant in the second method. Solar contribution factor (SCF) is the main criteria which has been used to evaluate the findings. Condenser duty with its associated water requirements, power penalty, and the required solar field land area are the parameters which have been investigated in the preset study. It has been found that the second configuration method has better impact on the performance of the plant and its associated cooling system than the first configuration method where zero power penalty is consumed in the second configuration as well as reducing the condenser duty with its related water usage amounts. In addition, it was shown that raw water withdrawal and consumption amounts in term of (gal/min)/MWnet decrease with increasing SCF in the first configuration where raw water withdrawal and consumption amounts are 7.23 (gal/min)/MWnet, and 5.17 (gal/min)/MWnet at SCF equals to 0 while these amounts reach to 6.74 (gal/min)/MWnet and 4.82 (gal/min)/MWnet at SCF of 0.95 respectively. On the other hand, these amounts increase with increasing SCF in the second configuration where water withdrawal and consumption values approach 6.75 (gal/min)/MWnet, and 4.92 (gal/min)/MWnet at SCF equals to 0 while the amounts are equal to 7.93 (gal/min)/MWnet and 5.81 (gal/min)/MWnet at SCF equals to 0.95 respectively despite that condenser duty is increasing in the both methods. This comes from the fact that the net produced power is increasing in the first scenario with SCF while it keeps constant in the second scenario. Furthermore, the relationship between the solar field's required land area and solar direct normal irradiation (DNI) was investigated in the present paper under four different SCF; 0.2, 0.4, 0.6, and 0.8. It was found that reducing the solar field's required land area requires increase in the DNI and decrease in the SCF where the reboiler heat duty is constant in the PCCC and the relationship is almost exponential. The validation was performed with an American governmental report (NETL, 2015) showing that the presented results has a significant agreement with the report.

2019

Water usage and energy penalty of different hybrid cooling system configurations for a natural gas combined cycle power plant—Effect of carbon capture unit integration

AuthorsSaif W. Mohammed Ali, Nasser Vahedi, Arindam Banerjee, Carlos Romero
JournalInternational Journal of Energy Research
Abstract

Electric power generation from thermoelectric power plants is associated with a negative impact on water availability, referenced as the water‐energy nexus, which is aggravated by climate change. In the present study, the effect of four different hybrid cooling system configurations on water usage and power penalty of a natural gas combined cycle has been investigated. The hybrid cooling system with a parallel connected indirect dry cooling system and wet cooling system is the most conventional studied hybrid cooling system in the literature, while the other studied hybrid configurations in the present study are novel regarding their effect on water requirement and power penalty. Simulations were conducted using the COCO 3.3 software and have been validated using data sets from a reference natural gas combined cycle plant, both with and without carbon capture unit, which is available in the literature. Four hybrid cooling system configurations were explored to evaluate their water requirements and power penalty. Other conventional cooling systems such as closed cooling, once‐through, and direct and indirect dry cooling methods were simulated with and without postcombustion carbon capture (PCCC) integration for comparison. It was found that the hybrid configuration, including indirect air‐cooled condenser and natural draft wet cooling tower, has the best performance as compared to the other conventional and hybrid cooling systems, amounting to 2.038 (gal/min)/MWnet, 1.573 (gal/min)/MWnet, and 12.29 MW for water withdrawal, consumption, and energy penalty, respectively, for the case of a unit without PCCC unit and 3.9 (gal/min)/MWnet, 2.928 (gal/min)/MWnet, and 15.177 MW for water withdrawal, consumption, and energy penalty, respectively, for a unit with carbon capture unit. It was confirmed that the PCCC integration approximately doubles the water withdrawal and consumption for all cooling systems. In addition, the indirect air‐cooled condenser and wet cooling tower is still the best performing cooling system with PCCC integration.

2012

Experimental and numerical studies of solar chimney for natural ventilation in Iraq

AuthorsKarima E. Amori, Saif Watheq Mohammed Ali
JournalEnergy an Building Journal
Abstract

Abstract Heat transfer process and fluid flow in a solar chimney used for natural ventilation are investigated numerically and experimentally her in. Solar chimney was designed, manufactured and tested by selecting different positions of air entrance namely: bottom entrance, side entrance, and both side and bottom entrances. The effect of integrating the chimney with paraffin (phase change material) on its thermal behavior has been also investigated. CFD analysis based on finite volume method is used to predict the thermal performance, and fluid flow in two-dimensional solar chimney under unsteady state condition, to identify the effect of different parameters such as solar radiation, and inclination angle. Experimental results show that a solar chimney with side entrance gives better thermal performance; also integrating solar chimney with PCM extended the ventilation period after the sunset. A comparison between the numerical and the experimental results shows fair agreement.

2025

Performance of Hybrid Parabolic Trough Collector Using Thermoelectric Generators: An Experimental Study

AuthorsNoorah. H. Almohamed, Saif Watheq Mohammed Ali
JournalIOP Conference Series: Earth and Environmental Science
Date2025-06-10
Abstract

Experimental analysis of a thermoelectric generator (TEG) and solar parabolic trough collector (PTC) is described in this paper. The TEG concept was created with the intention of using sun radiation as a source of heat. Stainless steel sheet (SSS) is used to construct the parabolic trough collector as its focused surface. The main component of the thermoelectric generator is the commercial thermoelectric module composed of bismuth telluride (Bi2Te3). The temperature of the cold side of TEG is stabilized by PCM's absorption of heat during melting. The focused solar radiation and the PCM-cooled heat sink provide the driving force behind the production of energy. Numerous operational factors are examined, including the temperature of the cold side, the receiver plate, the PCM's mean temperature, the power output, and the solar radiation. Results shows a maximum temperature of 99.8 °C was achieved with Concentrated solar radiation of 1996.9 W/m2.

2024

Static deflection of pre-twisted beam subjected to transverse load

AuthorsSaddam K. Al-Raheem, Hayder Zuhair Zainy, Aziz D. Almawash, Luay S. Alansari, Saif W. Mohammed Ali
JournalElsevier / Journal of Results in Engineering
Date2024-02-27
Abstract

In the current research, the static deflection of the pre-twisted beam has been calculated experimentally and numerically using finite element approach (ANSYS workbench 2020R1) and under the effects of different twist angles, different lengths, four boundary conditions of edges support of the beam. The beam was manufactured from PETG filament material by a 3D printer at room temperature. The obtained results showed reasonable acceptance between the experimental and numerical pre-twisted beam deflection. The numerical maximum deflection of the pre-twisted beam decreased with the increase of twisted angle of the beam for clamped-simply and simply-simply edges support. While it was irregularly various for clamped-clamped edge support with a minimum value of the maximum deflection occurred at the twist angle 135o. The maximum deflection of the pre-twisted beam is disappeared gradually at the twist angles greater than 270o for claimed-free edge support. In addition, the maximum deflection of the pre-twisted beam increased due to the beam length increment.

2024

Transient numerical simulation to investigate pressure fluctuation spectrum and deficit in the near wake of a horizontal axis wind turbine

AuthorsSaif W. Mohammed Ali , Muhannad Altimemy b, Hazim J. Jaber a, Nabeel A. Ghayadh
JournalElsevier/CellPress/Heliyon Journal
Date2024-06-03
Abstract

Wind energy becomes one of the promised solutions as alternatives of using fossil power energy in the upcoming decades. As pressure fluctuation and flow deficit in the near wake play a crucial role in predicting the turbine performance, the novelty in the current study focuses on a three dimensional (3 D) transient numerical simulation to investigate near wake characteristics of NREL phase IV wind turbine. Pressure fluctuation spectrum and wake deficit at four sections downstream the turbine are the main parameters studied as well as the flow streams and iso-surface characteristics. The mentioned parameters are studied at four sections: (0.25 D), (0.5 D), (0.75 D), and (1 D) of turbine diameter. The obtained results are compared with corresponding data from the NREL Phase IV experiments for validation purposes. Results show that the highest-pressure fluctuation spectrum would be at the nearest wake region, and, then it decreases periodically. Hub pressure spectrum density is much lower than that density for the turbine blade. The wake deficit profile shows that the deficit is developing with time at a rate equal to (0.115 rate per sec). In addition, it was found that the wake is recovered just (1 d) of the hub diameter while the blade wake deficit becomes the dominant after (0.75 D) of turbine diameter to cover the whole wake region. It was also found that the downstream distances should be extended more to resolve the whole wake recovery. The comparison with the tests measurements shows agreement between both the numerical and experimental works such that the error doesn't pass 4.3 %.

2023

Premixed flame characteristics for LPG/air mixture with CO2 dilution

AuthorsMohammed A. Al-Tayyar, Saif W. Mohammed Ali; Wisam J. K. Al-Obaidi; Haroun A. K. Shahad
JournalAIP Conference Proceeding
Date2023-12-22
Abstract

Functioning with providing alternative energy sources, finding new fuel mixtures, and diminishing the environmental and economic risks of combustion have become some of the most important challenges nowadays round world. Fuel type and composition significantly affect flame characteristics, which represent essential considerations for designing any combustion system. The current experimental study aims to investigate the characteristics and height of the premixed LPG flames with CO2 dilution. The investigation included testing four equivalence ratios (0.8, 1, 1.2, & 1.4), four CO2 dilution ratios (0%, 5%, 7.5%, & 10%). The un-burnt mixture flow rate varies between flame flashback and blowout limits in each case. It has been noticed that the equivalence ratio dominates flame height and flame aspect ratio for all mixture types and compositions at all operating conditions. The flame of LPG elongates from 35.8 mm to 56.5 mm when increasing the equivalence ratio from 1 to 1.4. The flow rate of the fuel/air mixture affects the flame height and flame aspect ratio positively. The addition of CO2 as a diluent gas elongates the flame, especially when increasing the equivalence ratio and/or flow rate since there is more than one influence, they all agree on the same effect on flame height. The flame stability limits expand with increasing the equivalence ratio and improve due to CO2 addition. The LPG-CO2/air mixture shows a better response to overcome flame flashback.

2025

Technical and economic analysis of retrofitting concentrated solar collector to generate the thermal energy required for the crude oil products distillation process

AuthorsSaif W. Mohammed Ali, Hussam H. Jabbar, Abbas K. Alshaibany
JournalKufa Journal of Engineering
Date2025-04-30
Abstract

Recently, most oil companies are working to reduce the cost and carbon emissions accompanied crude oil distillation process by developing suitable sustainable technologies. The present work studies the viability of retrofitting concentrated solar collector (CSC) represented by parabolic trough collector (PTC) through the crude oil distillation process in three stages; crude oil preheating in a furnace, live steam injection, and the reboiler heater. The whole oil distillation unit and the PTC unit are modeled and solved using an American software called COCO V 3.6.0.13 and SAM 2022.11.21 (System Advisor Model). Three different working fluids are investigated through the study: therminol VP-1, hitech solar salt, and pressurized water at different mass flow rates. Additionally, the proposed system was analyzed economically using levelized cost of energy (LCOE) method. The required land area for the solar unit is analyzed through the study too. It was found that hitec solar salt requires higher input flow rate than the other heat transfer fluids (HTF) where the maximum flow rate reaches about (75 kg/s) while the minimum flow rate was found for pressurized water as the flow rate value reaches about (25.7 kg/s). It was found also that the maximum required thermal energy is the energy exhausted in the furnace for crude oil preheating process, and the minimum value is the energy required for steam generation. The economic feasibility study shows that retrofitting such a solar units would be more beneficial in the years period between 2022-2050 as the LCOE of flue gas (0.0363 $/kWh) is higher than the LCOE of PTC (0.01604 $/kWh) leading to an overall cost saving reaches about 14523013 $ after year of 2021. The land area analysis shows that the required area is increasing linearly in a rate of (0.62 kW/m2). The validation with recorded data from literature shows a good agreement in compare with the current work.

2025

Concentrated Solar Thermal-Thermoelectric generator hybrid systems: Review on the Most Recent Developed technologies

AuthorsNoorah H. Almohamed , Saif W. Mohammed Ali
JournalIOP Conference Series: Earth and Environmental Science
Date2025-01-11
Abstract

Solar- (Thermoelectric Generator) TEG hybrid system has recently become the most widely studied and developed system. This paper focuses on the creation of solar-TEG hybrid systems and thoroughly assesses recent developments in solar-TEG hybrid energy technology. The study investigates the integration of concentrated solar thermal systems and photovoltaic (PV) cells with thermoelectric generators (TEGs). Studies on hybrid systems integrating concentrated solar units with TEG units have demonstrated encouraging outcomes in increasing energy conversion efficiency. Furthermore, it has been noted that phase change materials (PCM) and appropriate cooling systems are crucial for optimizing the performance of concentrated solar collector (CSC)-TEG or CSC-PVT-TEG systems. The potential of concentrated solar power (CSP) technology in areas with high solar irradiation is also covered in the study, focusing on the significance of connectivity opportunities and efficient energy generation. The current study considered the most recent development in solarTEG hybrid systems, the results highlight how important new ideas and cuttingedge technology are to expanding the field of solar energy use for sustainable energy solutions

Lectures

14

News & Announcements

10
News 2025-01-11

contribution in the fourth international conferenceRERA-2024

contribution in the fourth international conference RERA-2024

News 2025-01-11

Contribution in the fifth international conference ICSET-2024

Contribution in the fifth international conference ICSET-2024

News 2024-06-30

Participate in an international conference NICES 2024 as a presenter to a paper titled "Technical and economic analysis of retrofitting concentrated solar collector to generate the thermal energy required for the crude oil products distillation process."

paper was presented in the fourth conference of NICES 2024 at Al- Nahrain University from May 14- to May 15

News 2024-06-30

Participate in an international conference NICES 2024 as a presenter to a paper titled "Technical and economic analysis of retrofitting concentrated solar collector to generate the thermal energy required for the crude oil products distillation process."

paper was presented in the fourth conference of NICES 2024 at Al- Nahrain University from May 14- to May 15

News 2022-12-28

Contribution to the international fourth conference of the Al-Kafeel University

Two papers were presented in the international fourth conference of Al-Kafeel University by two scientific groups from university of Kufa, University of Babylon, Al Imam Al-Sadiq University, Sulaimani Polytech University. This Conference was held from 20-21 December 2022

News 2022-07-04

Contribution by presenting a paper in the 1 st International Conference on Achieving the Sustainable Development Goals

The contribution in the first international conference on Achieving the Sustainable Development Goals was done by presenting the results of work study conducting to desalinating salty water by using Solar Still system

News 2020-09-04

INTERNATIONAL CONFERENCE ON RECENT INNOVATIONS IN (ENGINEERING (ICRIE 2020

INTERNATIONAL CONFERENCE ON RECENT INNOVATIONS IN (ENGINEERING (ICRIE 202

News 2019-09-21

ASHRE EXP workshop in Georgia State/ USA

Saif attended number of workshops which have been developed by ASHRE in Georgia/ Atlanta for three days

News 2019-09-21

MIT Energy efficiency Conference

Attending the MIT Energy Efficiency Conference from April/03/2019 till April/05/2019

News 2019-09-21

Combustion Course at Princeton University

Attending Combustion course in Princeton University in the USA from June/24/2019 till June/30/2019

View details