مواقع التدريسيينجامعة الكوفة
0Publications
0Lectures
0Interests

About

Lecturer with 5 years of experience in analytical chemistry .
Having more than 4 scientific research group .Education
Baclories in chemistry /kufa I graduated and I was the third in my department
Master degree in analytical chemistry with distinction from kufa University/faculty of education for girls, Phd in analytical chemistry with distinction from Kufa University /faculty of education for girls.
Language
Arabic and English
Experience
First international scientific conference Arabic safety course, computer course, English course, laboratory safety course, preparation course for shiff rules, flow injection system design courseGraduate Studies Conference, University of Kufa, College of Education for GirlsPublished research
Solvation Method for Separation and Determination Zinc (II) and Acetophenone
Journal of Pharmaceutical Sciences and ResearchInternational Journal of Health
Sciences, 6(S4), 1623–1629.
International Journal of Health Science
Studying the some biochemical parameters for
thalassemia patients in AL-Najaf provincem‏
Int. J. Chem. Sci 13 (4), 2015‏
Skills: Teaching organic, inorganic, physical and bio chemistry, designing two systems of flow injection and successive injection, extracting drugs from different substances by new chemical methods, computer skills (Microsoft offce , windows and internet)

Research Interests

1

Publications

3
2022

Studying the Some Biochemical Parameters for Thalassemia Patients in AL-Najaf Province

Authorsنادية حبيب, صفا سليم زايد زينب عبد الله
JournalScopes,ScienceScholar
Abstract

The current study aims to study some biochemical indicators for thalassemia patients in the Najaf governorate, and the study included 25 patients with major beta thalassemia during the period from November 2019 to February 2020 and their ages ranged between (2-65) years and 15 healthy people who arenot He had genetic blood diseases and their ages ranged between (2-65) years. The results of the study showed that there are in some biochemical indicators, as there was a significant increase in the level of the enzyme of liver function ALT that was the focus in patients 23.74±29.53 U\L and in healthy people it was 4.61±11.67 U\L Also, the creatinine concentration patients 9.92±26.08 mmol\L and in healthy was, 68.06±51.54 mmol\L, Except for urea, we notice that there was a decrease in its concentration in patients 0.89±3.96 mmol\L

2019

Solvation Method for Separation and Determination Zinc (II) and Acetophenone

Authorsصفا سليم زايد, شوكت كاظم جواد
Journalof Pharmaceutical Sciences and Research
Abstract

By following Solvation technique with Acetophenone as organic agent for separation and determination zinc (II) so that Acetophenone through formation solvation species in the presence of salting out NNO3, as well as extraction solvation species into chloroform organic solvent The experimental studies shows 0.1 M NaNo3 was the optimum concentration of salting out in presence 90 pg of Zn2+ in 5mL aqueous solution and 10 minutes shaking time so that the extraction need 1x104 M acetophenone, the extraction procedure shows the presence of methanol in aqueous solution effect to enhancement the extraction efficiency. Comprehensive method 5 ml aqueous solution contain 50 pg of Zn2+ ion with 0.1 M NaNO3 salting out then added 5ml of 1x 10-4 M acetophenone dissolved in chloroform, shaking the solution for 10 min. afterward separation organic phase from aqueous phase, then measure the absorbance

2015

New design units in flow injection analysis and sequential injection analysis for Determination of copper (II) by analytical reagent

Authorsخديجة جبار , صفا سليم زايد
Journalمجلة Int. J. Chem. Sci
Abstract

A simple and facial flow injection method coupled with spectrophotometer detection was developed for determination of copper (II) using flow injection analysis (FIA) and sequential analysis (SIA). The FIA and SIA systems based on the reaction of copper (II) with EDTA at pH 4-5 with an absorption maximum at 732 nm. This study was performed with different physical and chemical parameters such as flow rate, reaction coil, volume of reagent (EDTA), volume of sample, pH medium and concentration of EDTA. The calibration curve was prepared and the dispersion coefficient, reproducibility and application were studied. Two methods, flow injection and sequential injection analysis were compared for determination of copper (II) by EDTA. The linear range was (0.6-12 mg/L),(1-16 mg/L) at sampling rate of 137, 114 sample per hour, the detection limits (0.218 mg/L),(0.136 mg/L) for FIA and SIA, respectively. Relative standard deviations for (10 mg/L), n= 10 were found (0.577% for FIA and 0.45% for SIA). Dispersion coefficient was also measured for the two methods.

Lectures

5
View details