مواقع التدريسيينجامعة الكوفة
0Publications
0Lectures
0Interests

About

• Name: Mahmood Shakir Naser
• Nationality: Iraqi
• Title / Role: Faculty Member | Department of Materials Engineering
• Academic Rank: Lecturer
• Degree: Ph.D. in Materials Engineering
• General Specialization: Materials Engineering
• Sub-Specialization: Biomaterials Engineering
• E-Mail: [email protected]
• Mobile: +964 7810 356 416
Education & Academic Qualifications:
1. B.Sc. in Materials Engineering – University of Kufa, Faculty of Engineering (2011)
2. M.Sc. in Materials Engineering – University of Kufa, Faculty of Engineering (2020)
3. Ph.D. in Materials Engineering – University of Technology, Department of Materials Engineering (2026)
Training Courses & Workshops:
1. Computer-Aided Design (CAD) using AutoCAD
2. CNC Milling Machine Design & Programming using VisualMill
3. Chemical Safety, Security, and Risk Assessment
4. X-Ray Powder Diffraction (XRD) Analysis & Operation
Research Interests: Corrosion Engineering, Heat Treatment Processes, Biomaterials, Orthodontic & Orthopedic Materials, Smart & Advanced Materials, and Mechanical Laboratory Testing.

Research Interests

1

Publications

6
2026

An in vitro evaluation of wettability and microbial adhesion of 316L stainless steel orthodontic archwires coated with Ag/PTFE nanoparticles

AuthorsMahmood Shakir Naser, Emad Al-Hassani and Fatima Al-Hassani
JournalBrazilian Dental Science
Date2026-05-20
Abstract

Objective: This study investigated how silver/polytetrafluoroethylene (Ag/PTFE) nanoparticle coatings influence the surface wettability and bacterial adhesion of 316L stainless steel orthodontic archwires against Streptococcus mutans and Staphylococcus aureus. Material and Methods: Stainless steel archwires were ultrasonically cleaned, sterilized, and coated using RF sputtering. The coated surfaces were characterized using XRD and AFM; wettability and bacterial adhesion were analyzed using contact-angle measurements and microbial assays. Results: The Ag/PTFE coatings produced uniform, smooth layers, increasing the contact angle from 72.96° (uncoated) to 135.35° (30 min sputtering) and reducing roughness from 45 nm to 18 nm. Adhesion of S. mutans and S. aureus dropped to 1.54 and 2.16 CFU/mL, respectively. Conclusion: RF-sputtered Ag/PTFE coatings enhanced hydrophobicity and reduced bacterial adhesion, suggesting improved oral hygiene during orthodontic treatment.

2025

Radio frequency sputtering of self-sanitizing material on NiTi archwires

AuthorsMahmood Shakir Naser, Emad Al-Hassani and Fatima Al-Hassani
JournalBIOMATERIAL INVESTIGATIONS IN DENTISTRY
Date2025-12-11
Abstract

Objective: The objective of this study was to coat orthodontic nickel titanium (NiTi) archwires with nano-particles (NP) of silver (Ag) combined with nano polytetrafluoroethylene (PTFE) to produce a smooth antimicrobial nanocomposite layer by using a radio frequency (RF) sputtering process and to evaluate the coated surfaces in terms of morphology, nano-roughness, adhesion strength, hardness, and antimicrobial activity. Materials and methods: Super-elastic NiTi archwires (diameter = 0.4 mm, length = 160 mm) were surface cleaned and sterilized prior to the RF sputtering, using a mixture of nano Ag powder (20 nm; purity > 99.95%) and PTFE powder (25 nm; purity > 99.95%). X-ray diffraction apparatus (XRD), flex atomic force microscopy (AFM) and field emission scanning electron microscopy (FESEM) were used to characterize the morphology and nano roughness of the coated archwires. Lactobacillus acidophilus (L. acidophilus) and Streptococcus mutans (S. mutans) were selected to evaluate the antimicrobial activity. Results: A uniform and homogeneous nanocomposite coating was obtained without agglomeration. Surface roughness values decreased with increasing sputtering time, while the coated samples exhibited excellent antibacterial activity against both bacterial strains. AFM analysis demonstrated that sputtering time strongly influenced adhesion resistance, hardness, and coating stability, and the antibacterial activity was highly effective against both L. acidophilus and S. mutans. Conclusion: The sputtering time of 30 min gave a smooth coating layer on the surface of NiTi archwire with strong antimicrobial resistance that offers significant potential for dental applications.

2025

Effect of Ag-PTFE nanocomposite coating on wettability and antimicrobial activity of orthodontic wires

AuthorsMahmood Shakir Naser, Emad Al-Hassani and Fatima Al-Hassani
JournalEngineering and Technology Journal
Date2025-10-02
Abstract

This study investigates the effect of Ag–PTFE nanocomposite coatings, prepared by radio frequency (RF) sputtering, on the surface and antimicrobial properties of orthodontic stainless steel archwires (SSW). The novelty lies in combining silver (Ag) and polytetrafluoroethylene (PTFE) nanoparticles into one coating, which has not been widely applied to orthodontics. The motivation is the need to reduce microbial adhesion and biofilm on archwires, which contribute to enamel demineralization, gingival disease, and infections. The problem addressed is the lack of coatings that can simultaneously provide enhanced surface properties, facilitate controlled silver ion release, and deliver durable antibacterial performance. Unlike literature that mainly studied Ag or polymer coatings separately, this work fills the gap by varying Ag and PTFE weight percentages and assessing their combined effects on wettability, roughness, ion release, and antimicrobial activity. Austenitic 316L stainless steel archwires (0.4 mm in diameter and 160 mm in length) were coated using Ag and PTFE nanopowders (30 nm). The coated SSW was characterized using field emission scanning electron microscopy (FESEM), X-ray diffraction (XRD), and contact angle measurements, while silver ion release was analyzed by atomic absorption spectroscopy. Antimicrobial efficacy was tested against Streptococcus mutans and Staphylococcus aureus. The results showed uniform coatings with distinct hydrophobic behavior and antibacterial activity. Increasing Ag content enhanced silver ion release and inhibition zones, while higher PTFE content increased hydrophobicity, reducing bacterial adhesion. These findings highlight Ag–PTFE coatings as a synergistic strategy to improve surface properties and suppress microbial colonization, suggesting potential benefits in preventing caries and periodontal complications.

2024

Energy absorption and impact response of ballistic resistance laminate

AuthorsZainab Shakir Radeef, Adnan A. Hussein , Zainab Talib Abid and Mahmood Shakir Naser
JournalOpen Engineering
Date2024-06-25
Abstract

High-speed impact performance has significantly expanded over the past few decades. The target response based on the impact conditions has been more difficult to visualise and evaluate. In this article, Ansys model analysis has been used to measure, visualise, and predict the projectile and target responses of Kevlar® (K) and Ramie® textile-reinforced unsaturated polyester resin (UP) matrix. The laminate thickness threshold was detected experimentally based on the highest stress intensity factor and energy release rates. Furthermore, tensile strength and bending of the laminate were found. The impact conditions have a significant impact on the target response; thus, an explicit dynamic analysis was used to visualise the impact response based on the number of target fixed supports (FSs). Two FS (2 FS) target absorbs 11% more energy than four FS (4 FS) target. Additionally, the target size has a major effect on the projectile and laminate responses, and a successful arrest of the projectile was detected in both cases. The smallest targets with 2 FS have the highest and wider response, where a successful change in the projectile trajectory was obtained.

2020

Electrophoretic Deposition of Nano-Composite Hydroxyapatite/Titania Coating on 2205 Duplex Stainless Steel Substrate

AuthorsAli Sabea Hammood, Mahmood Shakir Naser
JournalJOM
Date2020-11-04
Abstract

This paper reports on the electrophoretic deposition (EPD) process of hydroxyapatite/titania nano composite coatings on 2205 duplex stainless steel (DSS). A homogeneous thin coating was obtained using the EPD process at a potential of 30 V for 1 min. The microstructure of the coated substrate was identified by optical microscopy, atomic force microscopy (AFM), and scanning electron microscopy (SEM). The formed phases of the primary materials were analyzed by using X-Ray diffraction (XRD). The effects of deposition voltage on the kinetics of EPD at 20, 30 and 40 volts were identified. The corrosion behavior of coated and uncoated samples was studied in a Ringer's solution using potentiodynamic and cyclic polarization tests. A homogeneous morphology and crack-free structure was obtained with an optimum condition at 30 V with minimum porosity and the highest corrosion resistance. The current study showed an excellent corrosion resistance with a stability and suitability of these materials for medical purposes when used as a substrate coated with a bio-composite hydroxyapatite/titania layer.

2019

Effect of titanium oxide contents on the stability of HAp/TiO2 composite coating fabricated by electrophoretic deposition on 2205 duplex stainless steel for biomedical applications

AuthorsAli Sabea Hammood, Mahmood Shakir Naser
JournalElsevier
Abstract

This paper studies the electrophoretic deposition (EPD) technique of hydroxyapatite with different weight percent of TiO2 nanocomposite coatings on 2205 duplex stainless steel (DSS). The stability of the particles in the final suspensions containing various wt.% of TiO2 has been optimized by zeta potential test. After successful electrophoretic deposition from hydroxyapatite–titania, it was shown that suspension with 75 wt.% of hydroxyapatite and 25 wt% of titania nanoparticles has more stability than any other percent. SEM characterized the microstructure of the samples after the coating, while the elemental composition of the coating was examined using EDS. The functional groups and formed phases analyzed using FT-IR, and XRD. Then, the effects of deposition voltage and deposition time on the kinetic of EPD at 30 V with time intervals (1–4) min were identified. The corrosion behavior of all samples was tested in simulated body fluid (Ringer solution) using a potentiodynamic and cyclic polarization studies. A homogenous structure with a thin crack-free layer was obtained at EPD condition of 30 V-3 min. Moreover, the amount of porosity was minimum with the highest corrosion resistance of this coating. While the cyclic polarization results showed an improvement in the pitting corrosion resistance in the Ringer’s physiological solution and this would promote good biocompatibility for the coating.

Lectures

8
View details