مواقع التدريسيينجامعة الكوفة
0Publications
0Lectures
0Interests

About

B.Sc. from University of Kufa - Education college for girls - Chemistry department(1995, first succession on class), M.Sc. from University of Kufa - Education college for girls - Chemistry department in Analytical chemistry (solvent extraction )2000,and get on lecture surname at 2005 , and assistant professor surname at 2009. ph.D. get from Babylon university- Science college- chem. Department .Head chemistry department from 2013 to 2016 .
To obtain prize of president of ministers for the sovereignty carnival for the creativeness scientific.

Research Interests

1

Publications

7
2019

Spectrophotometric Detector Coupling with Flow Injection Analysis unit Using Dithizone Merging Zone Technique for Determination Cadmium (ll)

AuthorsKhdeeja Jabbar Ali
Journalpharmalionsnfo publicatpha
Abstract

A simple method using flow injection has been developed for the determination of Cadmium ion (II)), based on the reaction the Cd(II) ion with the Dithizone as reagent in acid medium . A standard or sample solution was injected into the Cadmium(II) stream (flow rate 4.2 ml /min) which was then merged with Dithizone in dilute acid. Under the optimum conditions, a linear calibration graph was obtained over the range of 1-10 μg /ml and the detection limit was 0.0188 μg /ml (s/n = 3). The relative standard deviation of the proposed method calculated from 10 replicate injections of 10 μg /ml Cadmium (II) was 0.160%. The sample throughput was 60 h−1.

2019

Sequential Injection Spectrophotometric Method for Determination Paracetamol in Pharmaceutical Formulations using N- bromosuccinimide and Methyl Orange as Oxidants

AuthorsKhdeeja Jabbar Ali
JournalJournal of Global Pharma Technology
Abstract

Sequential injection analysis (SIA) system is proposed for the determination of Paracetamol (PCT). PCT was determined by SIA based on the reaction between N-bromosuccinimide (NBS) and Methyl orange as reagent in found PCT in acid medium , yielding a red colour complex with absorption maximum at 507 nm., Under the optimum experimental conditions such as the flow rate and loading coil length , the reaction coil length ,

2019

Bead Flow Injection -Spectrophotometric System for Determination of paracetamol using N-Bromosuccinimide and Methyl Orange as Reagent and it Application

AuthorsKhdeeja Jabbar Ali
JournalMedwell
Abstract

A new system was designed using a column filled with beads (silica gel) properties to determination Paracetamol (PCT) using a reagentN-bromosuccinimide (NBS) the reaction is done according to the process of oxidation and reduction ,the wavelength was determined atλmax 507 nm, It was studied physical and chemical variables of the reaction such as such as the rate of flow and weight beads and study the effect of reaction time and effect of the reaction coil length , It has been found that the optimal concentration of hydrochloric acid 0.5 mol/L and KBr2% and the methyl orange concentration (8 × 10-4 ) mol/L and NBS (0.05) mol/L ,andstudy the volume of methyl orange,the detection limit was (3readings) where the value was equal to 0.046875 mg /L , the technique has been successfully applied to estimate PCT in multiple pharmaceutical samples .

2018

Determination of Zinc (II) Ion Using Dithizone by Flow Injection and Sequential Injection Techniques

AuthorsKhdeeja Jabbar Ali
Journaltsijournals.com
Abstract

Abstract This determinates Zinc (II) ion in variably samples by using methods flow injection and sequential injection systems which laboratory. The FIA and SIA systems depend on the base reaction of Zinc (II) ion with dithizone complex in aqueous phase in the presence of SDS anionic (sodium dodecyl sulphate) at pH=5 with absorption maximum at 565 nm. The factors (physical and chemical) effecting on the determination such as flow rats, reaction coil length, the volume of reagent (dithizone), the volume of sample, interference, the concentration of dithizone also.

2016

Design a flow injection system for determination of proteins using Coomassie Brilliant Blue G-250 Dye

AuthorsKhdeeja Jabbar Ali, Esraa Rasul Radhy
JournalJournal of Chemical and Pharmaceutical Sciences
Abstract

A new, rapid, and sensitive flow injection (FI) system with UV- VIS spectrophotometer detector has been notified for proteins determination; by measuring the absorbance at 595 nm at room temperature we obtain a good linearity between the absorbance and the protein concentration by range between (1-50) mg.l-1. The effecting chemical and physical parameters in the system have been studied, like solvent composition, dye concentration, flow rate, reagent volume, sample volume, reaction coil length. The method appropriate with many sugars, salts, acids and reducing agents, which is commonly exist in the biological solutions and dairy products. The sampling rate equal to 180 samples per one hour, detection limit is (0.326mg.l-1).Relative standard deviation for (30mg.l-1), n = 10 was found (0.824 %). The calibration curve was prepared. The dispersion coefficient, repeatability and applications were calculated. The method has been used to determine the protein concentration in dairy products, drug, and serum with retrieval between (71.36 -106.6). Key words: Flow injection analysis, Determination, protein, Coomassie brilliant blue.

2015

New spectrophotometric determination of copper (II) using an organic reagent derived from imidazole and 4-aminoantypyrine and applied onto different samples

AuthorsKhdeejaJabbar Ali, Layla Ali Mohammed, Fatima Jabbar Ali, Haider Norri Raheem
JournalJournal of Chemical and Pharmaceutical Sciences
Abstract

Ligand 2-[(4-antipyrinyl)azo)]imidazole were prepared and then react with metal salt in ethanol :water as asolvent in 1:1 ratio (metal : ligand) . The complex which have the general formula [CuLCI2.H2O]. ligand its metal complex are characterized using metal analysis by Infrared spectra, Electronic spectra,1HNMR spectral studies, Molar conductance , and Magnetic moment measurements, the measurements indicated that the ligand coordinate with the metal (II)ion in neutral tridentate manner. All the studies reveal coordination sixe for the metal in the complex. Octahedral structures are suggested for metal complex. Determining the trace amounts of Copper (II) was proposed in this paper. The methods was based upon the reaction of Copper (II) with 2-[(4- antipyriyl) azo] imidazole (4- APAA) as organic reagent in order to complex formation. The absorbance of complex, which is directly proportional to Copper (II) concentration at 578 nm. Various parameters that affect the signal response have been optimized in order to get the better sensitivity have been investigated. Absorbance was recorded at pH 8-9, with reagent concentration of 1×10 -5mol/l .The observed to be stable at various at temperatures (5-60) ˚C and for a longer period of time 1440 min. The calibration graph was linear in the range of 1×1-5–1×10-4mol/l. The practically detection limit was 1×1-6mol/l. Key word: Copper ion, Organic reagent, Determination

2015

NEW DESIGN UNITS IN FLOW INJECTION ANALYSIS AND SEQUENTIAL INJECTION ANALYSIS FOR DETERMINATION COPPER (II) BY ANALYTICAL REAGENT

AuthorsKHDEEJA JABBAR ALI, SAFA SALEEM ZIYED
JournalInt. J. Chem. Sci.
Abstract

A simple and facial flow injection method coupled with spectrophotometer detection was developed for determination of copper(II) using flow injection analysis (FIA) and sequential analysis (SIA). The FIA and SIA systems based on the reaction of copper (II) with EDTA at pH 4-5 with an absorption maximum at 732 nm. This study was performed with different physical and chemical parameters such as flow rate, reaction coil, volume of reagent (EDTA), volume of sample, pH medium and concentration of EDTA. The calibration curve was prepared and the dispersion coefficient, reproducibility and application were studied. Two methods, flow injection and sequential injection analysis were compared for determination of copper (II) by EDTA. The linear range was (0.6-12 mg/L), (1-16 mg/L) at sampling rate of 137, 114 sample per hour, the detection limits (0.218 mg/L), (0.136 mg/L) for FIA and SIA, respectively. Relative standard deviations for (10 mg/L), n = 10 were found (0.577% for FIA and 0.45% for SIA). Dispersion coefficient was also measured for the two methods. Key words: Flow injection, Sequential injection, Determination, copper.

Lectures

29
View details