Flat Slab–Column Modeling Using Finite
Element with Eccentric Loading Effects
الباحثونHaider A. A. Al‑Katib، Hayder H. Alkhudery1 · Aseel A. A. Al‑Katib1
المجلةIranian Journal of Science and Technology, Transactions of Civil Engineering
مختصر البحثAbstract
Slab–Column connection is one of the critical structural joints in building construction, since there are special design
requirements that must be achieved. This paper investigates RC slab–column connections under eccentric load using a
built-in 3-Dimensional Nonlinear program of fnite element in the pre- and post-cracking levels and up to the ultimate load.
The concrete is simulated as isoparametric brick element, and the reinforcement bar elements are assumed to be built into
isoparametric brick elements. With regard to load–defection responses and ultimate strength capacity, a good coincidence
is achieved for FEA and experimental results with maximum diference 1.6% for ultimate strength. In addition, the structural performance investigation of slab–column connection is carried in terms of the efectiveness of applied load types,
shear reinforcement and slab thickness. It can be concluded that the increase in loading eccentricity cause decreasing in
ultimate load 20.5 to 40% in comparison with case of e=0, which is one of conclusion of this research. Also, the use of
shear reinforcement (48 stirrups of Φ10 mm) in the fat slab connection with columns had more efects than slab depth. It is
found that the ultimate load capacity increases about 34.4% with e=0.0, while it decreases about 22% with e=0.45 m when
compared with slab–column connections without shear reinforcement (e=0.0). In addition, as the slab thickness increases
from 150 to 200 mm, the ultimate load increases about (25%) when compared with case of (e=0.0), while the ultimate load
increases about (2.3%) when compared with the same case of (e=0.0), which means that the increment in the slab thickness
can be considered as compensation for the efects of increasing in load eccentricity. Also, for the slab–column connection
without shear reinforcement, the related formula of ACI-code gives a good agreement in terms of ultimate load capacity in
comparison with the results of adopted FE model with maximum diference 4% as the unbalanced moment was increased,
while for usage of shear reinforcement in slab–column connection, the formula of ACI-code becomes more conservative
with maximum diference 10% with increasing of unbalanced moment.
ARTIFICIAL NEURAL NETWORK MODEL FOR FLEXURAL DESIGN OF CONCRETE HYDRAULIC STRUCTURES
الباحثونOday M. Albuthbahak and Hayder H. Alkhudery
Faculty of Engineering, University of Kufa, Najaf, Iraq
المجلةInternational Journal of Civil Engineering and Technology (IJCIET)
مختصر البحثAs a computer technique, Artificial Neural Networks (ANNs) have expanded in use with engineering fields. ANNs have been used in many civil engineering problems and some of them were used in the design of concrete structural elements and have shown a good degree of success. This paper presents an ANN model for the strength design of reinforced-concrete hydraulic structure according to the requirements of the Engineering Manual 1110-2-2104. Structural design is a sequential process needs iteration, assumption, checking the limits, ...etc, and that can be programmed with some judgments of the designer. 288 cases of design samples have been calculated using excel sheets and Microsoft visual basic programming language. 200 samples of design randomly selected have been used for training of (4-10-10-2) ANN model. 50 samples have been selected for validation, and 38 for prediction processes. The predicted design outputs were the thickness of hydraulic concrete section and corresponding steel reinforcements. Visual Gene Developer software of ANN prediction for general purposes has been used with a feed-forward neural network with a standard back-propagation learning process. The suggested artificial neural network model has predicted the output data of design for concrete sections, and the results have shown a satisfactorily match with the actual output data of design
INVESTIGATION OF EFFECTIVE HYBRID FRP AND STEEL REINFORCEMENT RATIO FOR CONCRETE MEMBERS
الباحثونHAYDER H. ALKHUDERY, ODAY M. ALBUTHBAHAK, and HAIDER A. A. AL-KATIB
Faculty of Engineering, University of Kufa, Najaf, Iraq
المجلةMeswell journal
مختصر البحثFiber reinforced material (FPR) has become an effective alternative reinforcement for concrete constructions owing to their higher ultimate strength in tension and strongly anticorrosive properties. However, the low ductility behaviour of FRP reinforcing concrete structure (FRP-RC) is appeared comparing to high ductility of conventional steel reinforcing concrete structures (S-RC). Successfully hybridization of reinforcement by combining FRP and steel rebar presents effective solution to migrate corrosion of steel rebar in steel reinforcing concrete constructions and advanced ductility of FRP-RC structures. Also, a good improvement is achieved in structural performances of concrete beams in terms of ultimate strength, central deflection, number cracks, and crack width. In this paper, a theoretical prediction analysis model of hybrid reinforcing concrete (H-RC) members reinforced by FRP and steel rebar presents. The moment-curvature relationship is predicted to achieve load-deflection curve and bending moment capacity of beams. A good agreement has been indicated from verification between results of predicted theoretical model and 19 experimental results of other authors. The hybrid reinforcement in HRC section can be replaced by equivalent steel ratio to conduct limitations of reinforcement ratio. The ductility index of H-RC members is measured to reference S-RC member, while the ultimate strength index is measured to reference FPRC member. A critical limitations of (
BEHAVIOR OF POLYPROPYLENE FIBERS
REINFORCED CONCRETE MODIFIED WITH
HIGH PERFORMANCE CEMENT
الباحثونHaider A. A. Al-Katib, Hayder H. Alkhudery, and Haider Ali Al-Tameemi
المجلةwww.iaeme.com/ijciet/issues.asp?JType=IJCIET&VType=9&IType=5
مختصر البحثFiber reinforced concrete is an improved type of concrete that containing fibers
randomly distributed inside it. Usually, the mechanical properties of concrete have been
developed namely, compressive, flexural, and tensile strength by adding the fibers. In
addition, the fiber makes the concrete very durable, tougher and lower permeability. This
paper aims to enhance the concrete mechanical properties by adding polypropylene fibers
in combination with high performance cement as a partial cement replacement. The
combination of both polypropylene fibers and high performance cement in concrete gave
excellent values of flexural, tensile and compressive strength. Seven percentages of
polypropylene fibers were used while two percentages of high performance cement were
used, in addition to normal specimens of concrete without any admixtures. Test results
give a well improvement by using both polypropylene fibers and high performance
cement. The flexural strength and the tensile strength are increased significantly from 2.7
to 14.5 MPa, and from 1.9 to 7 MPa, respectively. While concrete strength of compression
increased from 30.1 MPa to 42.9 MPa due to inclusion of polypropylene fibers and high
performance cement. The concrete specimens with including both high performance
cement and polypropylene fibers had adequate strength to counteract further cycles of
loading after releasing 1st failure load.
Finite element Investigation of Design Formula for Thin
Walled Plates Supported by Foam under Buckling Load
الباحثونHayder H. Alkhudery
Faculty of Engineering, University of Kufa
Haider A. A. Al-katib
Faculty of Engineering, University of Kufa
Aseel A. A. Al-Katib
Faculty of Engineering, University of Kufa
المجلةInternational Conference on Recent Innovation in Engineering , Science and Management (ICRIESM-2018)
مختصر البحثThe thin-walled plate and foam of low material is components of sandwich panels, one of the attractive engineering
structures mixed between different two materials to accomplish high ultimate strength integrated with light weight
structures. Usually, the sandwich panels composed of two thin steel faces with ultra-strength are supported and
separated between them by foam core. This paper deals with presently design expression of thin-walled steel faces
supported by foam simulated using finite element analysis (FEA). Numerous waves of FE models introduced to explore
and analyze the adequacy of present approach for thin-walled design. Also, investigation of FE simulation model
containing geometry, dimensions, loading system and supporting pattern are presented. The FEA model provides a good
acceptance with experimental results. However, for sandwich plate element with low (b/t) ratios, the formulae of design
appeared safety solution, while for high (b/t) ratios (slenderness plate) becomes over estimated. Finally, formula of
designing sandwich plate with local buckling is proposed in unification form.
Effect of Uplift Pressure under Hydraulic Structure Founded
on Isotropic and Anisotropic Soil
الباحثونAseel A. A. Al-Katib
Faculty of Engineering,University of Kufa
Haider A. A. Al-Katib
Faculty of Engineering,University of Kufa
Hayder H. Alkhudery
Faculty of Engineering,University of Kufa
المجلةInternational Journal of Engineering Technology Science and Research
IJETSR
مختصر البحثIn this research, “Slide” program was used to analyze seepage flow under the hydraulic structure through isotropic and
anisotropic soils and its effect on structures with cut-off at downstream, at upstream, and at both of them. The
distribution curves of uplift pressure along the floor had been reached at downstream for different degrees of anisotropy
from the horizontal axis. The effects of anisotropy on uplift pressure . The analysis process depends on a finite element
method. Eight-noded quadratic elements to represent the porous media. The maximum values of uplift pressure under the
structure with cut-off at downstream are seen at 180˚, and 0˚ inclination angles and the minimum values are seen at 90˚
inclination angle, the maximum values of uplift pressure under the structure with cut-off at upstream are at 90˚
inclination angle and the minimum values are at 180˚, and 0˚ angles, and the maximum values of uplift pressure under
the structure with cut-off at upstream and downstream are at 90˚ inclination angle and the minimum values are at 180˚,
and 0˚ inclination angles but the relationship is reversed after x=0.5. The quantity of seepage in downstream side of the
structure with a cut-off at downstream was 0.546 m3 /day, at upstream was 0.396 m3 /day, and at both of them was
0.501 m3 /day. The quantity of seepage for anisotropic soils was calculated for all cases.
KEYWORDS:pressure head,uplift pressure, seepage, isotropic soil and anisotropic soil.