مواقع التدريسيينجامعة الكوفة
فائز عبد مسلم عبد علي الوائلي
أستاذ مساعد

فائز عبد مسلم عبد علي الوائلي

English Version
0بحث منشور
0محاضرة
0اهتمام بحثي
0خبر

الملف الشخصي

شهادة البكالوريوس سنة 1997 باختصاص الهندسة الميكانيكية فرع التكييف والتجميد.
شهادة الماجستير سنة 2018 باختصاص الهندسة الميكانيكية فرع التكييف والتجميد/ تحويل طاقة
شهادة الدكتوراه سنة 2024 / تحويل طاقة

الاهتمامات البحثية

1

البحوث المنشورة

15
2022

Mechanical Properties of Graphene Oxide/Polyvinyl Chloride Composite Film

الباحثونAhmed A. Taher، Afrah Hassoon Oraibi Faez Abid Muslim Abd Ali
المجلةInternational Journal of Mechanical Engineering
مختصر البحث

In this study, graphene oxide (GO) particles were used as nanomaterials to improve the mechanical properties and performance of the GO/Polyvinyl Chloride (PVC) composite.Movie. Several mechanical tests were carried out on the resulting compound, including exploring the effect of GO contents on tensile strength and failure. Strain of GO/PVC composite film that the higher the GO content the higher the tensile strength. Then it gradually decreased when the GO content was greater than 2%, the film had a maximum tensile strength (77.6 MPa). This is more than 35% of the tensile strength of purity PVC film. The failure stress of the GO/PVA composite film decreased rapidly with increasing GO content. The explanation of the optimization mechanism of the compound is due to the presence of multiple hydrogen bonds between them Hydroxyl groups (-OH) from PVC and oxygen-containing functional groups from GO, and the effect of temperature and cooling on the resulting compound was studied.

2022

Performance of Single Solar Still with Different volume Pebble

الباحثونAfrah Hassoon Oraibi، ,Faez Abid Muslim Abd Ali2, Adnan A Hussein3, , Ahmed A. Taher
المجلةNeuro Quantology
مختصر البحث

The process of solar distillation and desalination is the process of purifying and removing salty water into good and pure water used for drinking and cooking. Solar energy: For the purpose of increasing the use of this type of energy, materials with the ability to store thermal energy in the basin are utilized solar panels, and these solar panels are made of composite wood material and stainless steel material with A glass pane tilted at an angle of 32 degrees on the horizontal surface. Solar energy is increased and saved through the use of pebbles that store thermal energy. Three different sizes, small and large, and a mixture of the two types of pebbles were used in Experimental analysis. Experimental results have proven that the small pebble is the best and maximum result that can be produced, up to 3.730 liters / m2 / per day

2022

Experimental Study of Thermal Conductivity of Neutral Particles Composite Materials

الباحثونHazim Jassim Jaber، Faez Abid Muslim Abd Ali, Al-Akaishi Ahmed Salih, Ahmed A. Taher
المجلةneuroquantology
مختصر البحث

Through this study, thermal conductivity of polymer hybrid composites filled with natural particles will be studied experimentally. In this study, A modified hot wire method is used to measure the thermal conductivity of the composites consisting of polyester matrix filled with neutral particles of date and olive up to 15% by weight ratio. With the increase in the density of natural materials, date kernel powder and olive powder additives to polyester to form the compounds filled with it, there is an irregular increase in the thermal conductivity. With increasing the temperature, thermal conductivity decreases to give good insulated composite material.

2022

Review of Water Cooling Techniques for Enhancement Performance of Photovoltaic Panel

الباحثونFaez Abid Muslim Abd Ali، Ahmed A. Taher, Muna Hameed Alturaihi
المجلةTurkish Journal of Computer and Mathematics Education
مختصر البحث

This study discusses various water-based cooling solutions for lowering the operative temperature of the electrical phenomena panel The goal of this review study is to improve the performance of micro electrical phenomenon the panel temperature the impact operative and temperature panel of electrical phenomena is explored using a variety of cooling strategies The advantages and disadvantages of evaporative cooling, water spray cooling, and immersion cooling were investigated in this research in order to determine their impact electrical phenomenon was well known evaporating cool system, which uses cold water to cool it, has effect with electrical phenomenon performance As a result, in a very hot climate, cool water was the ideal so improve electrical potency of electrical phenomenon.

2021

Effect of Central and Linear Holes on Thermal Behavior Based on Babylonian Clay

الباحثونBasil N. Merzha، Suadad noori ghani Faez Abid Muslim Abd Ali
المجلةJournal of Mechanical Engineering Research and Developments
مختصر البحث

This article examined the effect of central and longitudinal vents on the thermal behavior of the slurry compound Mineral analyzes of the used clays were performed to find the composition of the components for the clay. It was thermal characterization, In a hot cylinder fashion. The thermal transfer analysis, thermal resistance, energy saving and density fraction were extracted in a practical way. This study is important to know the effect of internal gaps on thermal conductivity during the manufacturing process, From the extracted girls, it was found that the central openings dissipate heat and reduce the conductivity, and it is less compared to the longitudinal openings.

2020

Enhancement the Performance of Compression Refrigeration Cycle by Cooling Condenser Air in Hot Climate

الباحثونFaez Abid Muslim Abd Ali، Muwafaq Sh. Alwan Laith Jaafer Habeeb Humam Kareem
المجلةJournal of Mechanical Engineering Research and Developments
مختصر البحث

The present work, an experimental study has been carried out to investigate the effect of cooling condenser air to the performance of vapor compression refrigeration cycle, which decreases in coefficient of performance because of the increase in ambient air temperature. The experiment rig was constructed by using aluminum box contain the outdoor of spilt unit and evaporative cooling pad that pour water on it from the water tank by small water pump and rubber tube, to evaporative cooling for air which cooling the condenser cycle. The experimental thermal results proved that this method is successful to decrease air temperature that lead to cooling the condenser and decrease the presser and temperature of the refrigerant and lead to improve all the properties of the cycle. The coefficient of performance of the system is enhancing in a rate of 39% as a result of increase the refrigeration effect and decrease the compressor work in a rate of 18% and 34% respectively. The decrease in temperature of exit air from condenser by evaporative cooling compare with dry condenser air and the ambient in a rate of 46% and 29.5% respectively. The consumption of electric power decreased in a rate of (25-32) % compared with dry system.

2020

The Rooms Air Conditioning by Cooling the Conventional Water Tank Using Hot Summer Air and Solar Energy

الباحثونHasan Shakir Majdi، Faez Abid Muslim Abd Ali Laith Jaafer Habeeb
المجلةInternational Journal of Heat and Technology
مختصر البحث

In the present work, an experimental study has been carried out to investigate a method to reduce the water tank temperature and used it in room air condition. The tests were conducted in the hot season (July and August) in Iraq. The results proved that the device succeeded in reducing the water tank temperature to 23℃, which is a low temperature in the summer and kept at this value by continuous work of the device. It was almost constant at the hot afternoon compared to the temperature of the uncooled tank, which reached its temperature at 2:00 pm to about 43℃ and the difference was 46.5%. The dry air temperature of the test room is very close to the temperature of the house room air (30-33) ℃, compared to the ambient temperature (45-50) ℃. Decrease in the relative humidity to (51-45) % for the test room compared with house room (94-90) %. The power consumption of the system is lower than traditional air evaporative cooler in a rate of 67%.

2020

Cooling of a Vertically Oriented Air-Ventilated Square Cavity

الباحثونHazim Jassim Jaber، Ali Abd Al-Nabi Abaas Faez Abid Muslim Abd Ali
المجلةJournal of Mechanical Engineering Research and Developments
مختصر البحث

This numerical analysis is performed to investigate the performance of mixed convection in a vertically oriented air-cooled square cavity. One inlet/outlet placement configuration, when both the inlet and the outlet ports are located at the same bottom side, is considered. The numerical approach is based on the finite volume method integrated in an in-house formulated FORTRAN code to computationally solve the twodimensional Naiver Stock and energy equations with corresponding boundary conditions. The effect of aiding buoyancy on the flow field in a vertical downward laminar jet is examined for Richardson number (0 ≤ Ri ≤ 5) and Reynolds number (25 ≤ Re ≤ 100), with constant physical properties. The results indicate that the increase in Reynolds number increases significantly the average Nussle number; however, the increase in Richardson number slightly affect the amount of heat removal from the cavity. The fundamental nature of the resulting interaction between the buoyancy driven flow and the forced external flow demonstrated by the patterns of the streamlines and isotherms. Importantly, it is found that the placement configuration considered provides unfavorable flow and thermal distributions, and is not beneficial for heat elimination, for most of Reynolds and Richardson values.

2020

Numerical Investigation of Heat Transfer in Enclosed Square Cavity

الباحثونReyadh Ch. Al-Zuhairy، Muna Hameed Alturaihi Faez Abid Muslim Abd Ali
المجلةJournal of Mechanical Engineering Research and Developments
مختصر البحث

Numerical investigation was performed to investigate the convection heat transfer in a square cavity that have been vented vertically. Different values of Reynolds number used (50, 100, 200, and 250) with three different opening to side length ratio (S/L) in the cavity (0.1, 0.2, and 0.3). Richardson number varied between (1, 5, and 10). Galerkin finite element utilized for the numerical simulations, the numerical model was validated and the result obtained was acceptable. The results showed that as Reynolds number increase inside the cavity, the Nusselt number is also increased. From the inlet opening of the cavity to the exit, Nusselt number seamed to decrease. Increasing the value of Richardson number at the same value of Reynolds number increases the Nusselt number within the cavity. Streamlines patterns and isothermal patterns were also shown for the mixed convection flow inside the cavity.

2018

Solar Panel Cooling and Water Heating with an Economical Model Using Thermosyphon

الباحثونLaith Jaafer Habeeb، Dheya Ghanim Mutasher , Faez Abid Muslim Abd Ali
المجلةJordan Journal of Mechanical and Industrial Engineering
مختصر البحث

In the present work, experimental and theoretical study has been carried out to investigate the effect of using heat thermosyphon on the performance of cooling photovoltaic thermal solar panel

2017

Cooling Photovoltaic Thermal Solar Panel by Using Heat Pipe at Baghdad Climate

الباحثونFaez Abid Muslim Abd Ali، Laith Jaafer Habeeb Dheya Ghanim Mutasher
المجلةInternational Journal of Mechanical & Mechatronics Engineering
مختصر البحث

This paper represents an experimental investigation of cooling the photovoltaic panel by using heat pipe.

2025

Experimental evaluation of vortex generators for enhancing solar photovoltaic panel performance with parabolic reflectors

الباحثونM. Sheikholeslami، F.A.M. Abd Ali
المجلةSolar Energy Materials and Solar Cells
التاريخ2025-01-09
مختصر البحث

of a CPVT (concentrated photovoltaic thermal) system. The CPVT system was tested using a single-axis solar tracking mechanism and a parabolic solar collector that concentrated solar radiation onto a photovoltaic thermal (PVT) module. The cooling system utilized water, and two different geometries—one without VGs and one with VGs—were tested across various flow rates to assess their influence on system performance. The CPVT system consisted of eight monocrystalline solar modules interconnected in parallel to maximize energy collection. The experiments were conducted in Najaf, Iraq, on July 27, 28, 30, 31, and August 2, 2023. Data collection was carried out at 20-min intervals from 10:20 to 14:00 on each test day. Environmental conditions were carefully monitored and recorded using precise measurement instruments. Key performance indicators, such as electrical and thermal efficiencies, were analyzed at various times throughout the day. The results revealed that enhancing the cooling of the solar cells significantly improved their power production capabilities and longevity. Given Iraq’s hot climate, where temperatures can reach extreme levels, effective cooling is crucial to prevent long-term damage to the solar cells. The study found that increasing the coolant flow rate led to a significant improvement in thermal efficiency, with an average enhancement of 22.07 %. The introduction of VGs resulted in substantial gains, with average thermal efficiency increasing by 15 % and electrical efficiency by 23 %. The overall efficiencies of the CPVT systems were recorded as 64.31 % without VGs and 74.81 % with VGs, highlighting a marked improvement in performance due to the incorporation of VGs. This study emphasizes the critical role of effective thermal management in CPVT systems, particularly in hot climates, where the risk of thermal degradation is high.

2023

Thermoelectric-Driven Room Air Cooling via a Multi-U Shaped Heat Sink System

الباحثونFaez Abid Muslim Abd Ali، Safaa Mohemmed Ali Mohemmed Reda Mohammed A. Mahmood Hussein
المجلةInternational Journal of Heat and Technology
التاريخ2023-08-31
مختصر البحث

The compact sizing and lightweight characteristics of thermoelectric devices have garnered significant attention, leading to their widespread use across varied fields. This study experimentally investigates the application of thermoelectric refrigeration in air conditioning, employing a moderately designed system. A unique, multi-U shaped heat sink system was developed, wherein thermoelectric devices were affixed onto rectangular tubes befitting their dimensions, thereby facilitating water as an auxiliary medium for energy transfer. This design enabled the transformation of cold water from the system's cold side to the indoor unit's water-air heat exchanger, while hot water was directed to the outdoor evaporative cooling tank. A Peltier-type thermoelectric device was harnessed for this experiment. The devised setup was subjected to multiple tests to evaluate its thermal performance under the climate conditions of Najaf. Preliminary results validated the effectiveness of the water cooling methodology, with the water temperature observed to decrease to 14℃. Consequently, the room air was cooled by the water-air heat exchanger, reaching temperatures between 20℃ and 24℃. This study underscores the potential of integrating thermoelectric devices with innovative heat sink designs for efficient room air cooling.

2024

Enhancing Thermal Efficiency in Solar Water Heaters Using Reflective Mirrors

الباحثونQusay J. Abdul-Ghafoor، Faez Abid Muslim Abd Ali Wajeeh K. Hasan Karrar A. Hammoodi
المجلةInternational Journal of Design & Nature and Ecodynamics
التاريخ2024-02-29
مختصر البحث

With the development of solar energy collection technologies and the mechanism of exploiting solar energy as renewable energy, it was necessary to develop a solar vacuum tube system, which is considered one of the old systems with little efficiency. In order for the development process to be completed, it was necessary to place side reflectors that border the pipes from all sides to better reflect solar radiation and raise the temperature of the pipes to the required level. The optimal angle for increasing temperature was determined by adjusting the sidewalls of mirrors, adjusting the wall width, and comparing angles at various angles (30, 40, 50, 60, 70, 80, 90) degrees, to achieve the best results. The angle of the mirrors on the pipes is adjusted from 30 to 90 degrees, as well as their width from 250 mm to 500 mm, and from 5 a.m. to 5 p.m., with a difference of one hour each reading. The temperature gradient on solar collector tubes increases with time and mirror angle, reaching maximum at noon and 30 degrees. Infrastructural radiation increases significantly at 30 degrees, reaching 700 W/m2. The width of the mirror wall affects radiation reflection and distribution, with a 500 mm width being more effective. The 30-degree angle had the highest thermal efficiency at 84%, while a 500 mm width difference achieved 86%. The novelty of the work varies in terms of developing the thermal efficiency of the solar collector by adding these influential factors to it.

2024

Influence of vortex generator on performance of concentrated solar photovoltaic module in existence of heat sink

الباحثونM. Sheikholeslami ، Faez.A.M. Abd Ali
المجلةApplied Thermal Engineering
التاريخ2024-06-20
مختصر البحث

New configuration of concentrated photovoltaic thermal (CPVT) with the implementation of parabolic concentrator and heat sink combined with the vortex generator (VG) were presented in current work. The testing fluid is water and temperature-dependent features were utilized. The regime of water flow in absence and presence of VG are laminar and turbulent, respectively. Numerical simulations were done for different values of angle of VG (θ = 30◦, and 60◦), pitch ratio (S = 0.025, 0.0375, and 0.05), and volumetric flow rate (Q = 0.5, to 2 Lit/min). Four values for width of reflector have been applied and radiation model was utilized to derive the absorbed heat flux. The accuracy of modeling has been examined for three cases and good accommodations have been reported. The maximum values of thermal (ηth) and electrical (ηel) performance are 63.75 % and 13.96 % which happens when θ = 30◦, S = 0.025, Q = 2 Lit/min. Installing VG leads to increments of ηth and ηel about 1.42 % and 2.74 %. Increase of S and θ cause performance to decrease while this function increases with rise of Q. Increase of Q causes ηth and ηel to increase about 1.17 % and 2.55 % for the best case.

المحاضرات

10

الأخبار والإعلانات

8
الأخبار 2026-08-10

دورة مسار بولونيا في الجامعات العراقية

احد دورات منصة ايدوبا التابعة لوزارة التعليم العالي

الأخبار 2026-08-10

اسباب رفض المقالة البحثية وكيفية تجاوزها

احد دورات منصة ايدوبا التابعة لوزارة التعليم العالي

الأخبار 2026-08-10

المجلات الرصينة

احد دورات منصة ايدوبا التابعة لوزارة التعليم العالي

الأخبار 2026-08-10

ملاحظات لكتابة ونشر بحث مراجعة

احدى دورات منصة ايدوبا التابعة لوزارة التعليم العالي

الأخبار 2026-08-10

فكرة معامل هيرش وكيفية زيادته

احدى دورات منصة ايدوبا التابعة لوزارة التعليم العالي

الأخبار 2026-04-22

فعاليات الاسبوع المهدوي

بتاريخ 2026/2/9 تمت المشاركة في اقامة مهرجان الاسبوع المهدوي في كلية الهندسة

الأخبار 2022-12-28

زيارة ميدانية علمية للطلبة للعتبة العلوية المقدسة لغرض الاطلاع على عمل وتصميم منظومات التكييف والتجميد

ببداية الفصل الدراسي الاول لسنة 2021 تم اطلاع طلبة المرحلة الثالثة والرابعة لفرع التكييف والتجميد لموقع منظومات والاجهزة وكذلك دافعات الهواء ودكتات الهواء وانابيب الماء المجهزة للتكييف والشرب

الأخبار 2022-12-28

ورشة عمل تطوعية

لأجل تطوير المهارات العملية في مادة منظومات التكييف والتجميد لطلبة المرحلة الرابعة تم اجراء ورشة عمل تطوعية بناء على طلبهم بتاريخ 11-12/5/2022 وتم تجهيز المواد اللازمة بالتعاون مابين الاستاذ والطلبة حيث تم طرح المواضيع المدرجة في ادناه وتوزعت محاضرات الورشة بين مختبرات قسم الميكانيك وورش الكلية وكما يلي:- 1- التعرف على الاجزاء الرئيسية لمنظومات التكييف والتجميد واهم الاعطال والمشاكل التي تتعرض لها. 2- التعرف على انواع الانابيب وطرق تنظيفها ولحامها وربطها وطيها حيث قام الطلبة بلحام وعمل توسعة وربط الانابيب بكل انواعها. 3- التعرف على كيفية فحص تسرب مائع التثليج ومعالجته والتفريغ والشحن. 4- التعرف على الدوائر الكهربائية للاجهزة ومكوناتها وطريقة ربطها وكيفية تحديد الاعطال التي تطراء عليها. 5- التعرف على بعض الملحقات والعدد والاجهزة المهمة والضرورية في فحص وصيانة اجهزة التكييف والتجميد. 6- تم توثيق الورشة بالصور في القرص المدمج (CD) المرفق طيا.

عرض التفاصيل