EFFECT OF BOLT DIRECTION ON THE BEARING CAPACITY OF DOUBLE SHEAR CONNECTIONS
بحث النوع:
هندسة التخصص العام:
Salah Talib Nimnim اسم الناشر:
Faris A. Jawad Mohammed Abed Attiya اسماء المساعدين:
Kufa Journal of Engineering الجهة الناشرة:
Kufa Journal of Engineering  
2016 سنة النشر:

الخلاصة

The direction of bolts and its effect on the bearing capacity of double shear bolted connections has been examined in this paper. Sixteen specimens with up to four bolts have been tested under tensile load. These specimens have been sorted into two series (L, T) according to the bolt direction with applied loads The experimental results have clearly indicated that the bearing capacity of connections had been considerably affected by changing the direction of bolts. With tear-out failure, All specimens of L series showed high bearing capacity and good ductility while block shear failure was the distinguishing feature of specimens of T series. الخلاصة اتجاة البراغي وتاثيرها على سعة التحمل للوصلات المزدوجة تم اختباره في هذا البحث . تم فحص ستة عشر نموذج. لقد تم تصنيف النماذج الى مجموعتين وحسب اتجاه البراغي مع القوه المسلطة . وقد اثبتت النتائج بان السعه التصميمية للوصلات المزدوجة تتاثر تاثيرا كبيرا بتنغير اتجاه البراغي وان النماذج التي بها البراغي باتجاة القوه اظهرت قوة تحمل عاليه مع مطيلية عالية وانها جميعها فشلت بخلع البليت بالكامل بينما فشل القص كان هو السمه السائدة لمجموعة النماذج ذات البراغي الموضوعة باتجاة عرضي مع القوة المسلطه